SECTION 235216 - CONDENSING BOILERS - AERCO
Capacity:1-20t/h
Rated thermal efficiency: 100-104%
Fixed working pressure: ≤1.6MPa
Applicable fuel:natural gas etc.
Capacity:0.7-14MW
Rated thermal efficiency:96-98%
Fixed working pressure:≤1.25MPa
Applicable fuel:Natural gas, light oil, etc.
Capacity:0.7-2.8Mw
Rated thermal efficiency: 97.2-106%
Fixed working pressure:0.1MPa
Applicable fuel:Natural gas, etc.
Capacity:2.8-7.0Mw
Rated thermal efficiency:≥105.5%
Fixed working pressure:-0.02MPa
Applicable fuel:Natural gas, etc.
Capacity:99Kw
Rated thermal efficiency:97.2-104.4%
Fixed working pressure:1.0MPa
Applicable fuel:Natural gas, etc.
Capacity:0.5-4.0 t/h
Rated thermal efficiency:98%
Fixed working pressure:≤1.25MPa
Applicable fuel:electric energy
Condensing Boilers | AERCO. Condensing Boilers Superior Reliability and Reduced Cost of Ownership An industry leader in water heating design for 65 years, AERCO was the first to introduce commercial condensing, fully modulating boilers. We continue to improve upon our innovative technologies and advanced designs.Get Price
Aug 21, 2020 · Aerco Benchmark Boiler Sequencing Technology Easy Setup (C-more Controller) This service tip of the month is a quick start guide to setting up the built-in sequencing controls in Aerco Benchmark boilers with C-More controllers. This built-in boiler sequencing technology (BST) that is standard on every Aerco Benchmark boiler has many features to Get Price
c. Section 233113 Metal Ducts contains the requirements for combustion air materials, instead of the plastic materials named in Section 235216 Condensing Boilers paragraphs 2.2.O.2. and 2.3.I.2. ACS Control: a. We recommend we keep the Aerco ACS controller in the design. QUESTION #2: "Can you tell us who owns the roof warranty?" ANSWER #2Get Price
MASTERSPEC Full Length SECTION 235216 – CONDENSING … MASTERSPEC Full Length CONDENSING BOILERS 235216-1 D. AHRI Compliance: Boilers shall be AHRI listed and must meet the minimum efficiency specified under AHRI BTS-2000 as defined by Department of Energy in 10 CFR Part 431. E. ANSI. Read MoreGet Price
Drawings and general provisions of the Contract apply to this Section, including General and Supplementary Conditions and Division 01 Specification Sections. SUMMARY. This Section includes packaged, factory-fabricated and -assembled, gas-fired, high efficiency condensing domestic water heaters, trim and accessories for generating hot potable water.Get Price
section 235216 - condensing boilers G. Blower: The boiler shall include a VFD controlled or constant speed fan to operate during the burner firing sequence and pre-purge the combustion chamber. Motors: Blower motors shall comply with requirements specified in Division 23 Section "Common Motor Requirements for HVAC Equipment."Get Price
Jun 16, 2019 · AERCO International, Inc. is a manufacturer and supplier of commercial condensing boilers, high efficiency water heating equipment and energy recovery systems in the HVAC/plumbing industry across a variety of markets including education, lodging, government, office buildings, healthcare, industrial and multifamily housing. In 1949, AERCO introduced the …Get Price
Mar 04, 2010 · LBNL Facilities Master Specifications 235216-2Revised Condensing Boilers03/04/2010 SECTION 235216 – CONDENSING BOILERS GENERAL SUMMARY This Section includes packaged, factory-fabricated and -assembled, gas-fired, [pulse-combustion] [fire-tube] [water-tube] [water-jacketed] condensing boilers, trim, and accessories for generating hot water.Get Price
23 5216 - 3 CONDENSING BOILERS B. Unit: Metal membrane wall, water or fire tube, condensing boiler on integral structural steel frame base with integral fuel burning system, firing controls, boiler trim, insulation, and removable jacket, suitable for indoor application. C. Electrical Characteristics: 1. Refer to Section 26 2717.Get Price
15-008 Ohio Utilities Protection Service – New Office Building – Bid Package B CONDENSING BOILERS CONDENSING BOILERS 23 52 16 - 3 PART 2 - PRODUCTS 2.1 FIRE-TUBE CONDENSING BOILERS A. Manufacturers: Subject to compliance with requirements, provide products by one of the following: 1. AERCO International. 2. Bosch Thermotechnology Corp. 3.Get Price
CONDENSING BOILERS 235216-1 SECTION 235216 - CONDENSING BOILERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to …Get Price
SECTION 235216 - CONDENSING BOILERS. 292 Chapter 14 Stack—an opening at the top of the boiler that is used to remove flue gas, p. 297. Steam drum—the top drum of a boiler where all of the generated steam is collected before entering the distribution system, p. 293.Steam trap—a device used to remove condensate or liquid from steam systems, p. 294.Get Price
MASTERSPEC Full Length SECTION 235216 – CONDENSING … This Section includes packaged, factory-fabricated and -assembled, gas-fired, fire-tube condensing boilers, trim, and accessories for heating hot water. 1.3 SUBMITTALS A. Product Data: Include performance data, operating characteristics, furnished specialties, and accessories. B.Get Price
Please clarify what make and model boiler is the intent of the design. Specification Section 235216 calls out Aerco Benchmark 2000's but the Boiler Schedule on drawing M400 calls out Weil McLain SF 550's. Answer #6: Refer to Revised Specification Section 235216 "Condensing Boilers", attached as part of this Addendum. Question #7Get Price
SECTION 235216 - CONDENSING BOILERS SECTION 223436.23– HIGH EFFICIENCY GAS DOMESTIC WATER HEATERS GENERAL RELATED DOCUMENTS Drawings and general provisions of the Contract apply to this Section, including General and Supplementary Conditions and Division 01 Specification Sections. SUMMARYGet Price
SECTION 235233.19 – COPPER WATER-TUBE BOILERS. This Section uses the term "Architect." Change this term to match that used to identify the design professional as defined in the General and Supplementary Conditions. Verify that Section titles referenced in this Section are correct for this Project's Specifications; Section titles may have changed.Get Price
SECTION 235216 - CONDENSING BOILERS. Boiler shall be factory-fabricated, factory-assembled and factory-tested, fire-tube condensing boiler with heat exchanger sealed pressure-tight, built on a steel base, including insulated jacket, flue-gas vent, combustion-air intake connections, water supply, return and condensate drain connections, and controls.Get Price
CONDENSING BOILERS 235216-1 SECTION 235216 – CONDENSING BOILERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to …Get Price
MASTERSPEC Full Length SECTION 235216 – CONDENSING … This Section includes packaged, factory-fabricated and -assembled, gas-fired, fire-tube condensing boilers, trim, and accessories for heating hot water. 1.3 SUBMITTALS A. Product Data: Include performance data, operating characteristics, furnished specialties, and accessories. B.Get Price
2.1 FIRE·TUBE CONDENSING BOILERS A. Basis-of-Design Product: Subject to compliance with requirements, provide product indicated on Drawings or comparable product by one of the following: 1. Fulton Boiler Works, Inc 2. AERCO International. CONDENSING BOILERS W0175002/K1169 235216 -2 • • • • • • • • • • • • • • • •Get Price
CONDENSING BOILERS 235216 - 1 SECTION 235216 - CONDENSING BOILERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. 1.2 SUMMARY A. This Section includes packaged, factory-fabricated and Get Price
CONDENSING BOILERS 235216 - 1 SECTION 235216 – CONDENSING BOILERS PART 1 - GENERAL 1.1 DESCRIPTION OF WORK A. Condensing boilers 1.2 RELATED DOCUMENTS A. Drawings and general provisions of the Contract apply to this Section, including General and Supplementary Conditions and Division 01 Specification Sections. 1.3 SUBMITTALSGet Price
FIRE TUBE CONDENSING BOILERS 235216 - 1 SECTION 235216 – FIRE-TUBE CONDENSING BOILERS . PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. 1.2 SUMMARY A.Get Price
Warranty Period for Water-Tube Condensing Boilers: 10 years from date of Substantial Completion. 1.4 Specification Section 235216 - CONDENSING BOILERS: Delete Paragraph 2.1.A and 2.1.B. 1.5 Specification Section 235216 - CONDENSING BOILERS: Add Paragraph 2.1.C.4 AERCO Benchmark boiler.Get Price
SECTION 235216 - CONDENSING BOILERS - aerco. Liming · SECTION 235216 – .75-6 MMBTU BENCHMARK STANDARD SERIES CONDENSING BOILERS. PART 1 - GENERAL. 1.1 RELATED DOCUMENTS. A. Drawings and general provisions of the Contract apply to this Section, including General and Supplementary Conditions and Division 01 Specification Sections. Get Price
A. Basis-of-Design is the MFC Series Condensing Boilers as supplied by AERCO International Inc. Equivalent units and manufacturers must meet all performance criteria, and will be considered upon prior approval. END OF SECTION 235216. MASTERSPEC Full Length 6/11/2019. 3-10 MBTU CONDENSING BOILERS 235217 - 1. Title: SECTION 235216 Get Price
MASTERSPEC Full Length SECTION 235216 – CONDENSING … This Section includes packaged, factory-fabricated and -assembled, gas-fired, fire-tube condensing boilers, trim, and accessories for heating hot water. 1.3 SUBMITTALS A. Product Data: Include performance data, operating characteristics, furnished specialties, and accessories. B.Get Price
Drawings and general provisions of the Contract apply to this Section, including General and Supplementary Conditions and Division 01 Specification Sections. SUMMARY. This Section includes factory packaged, factory-fabricated and -assembled, gas-fired, high efficiency condensing domestic water heaters, mounted on support structure with Get Price
Jul 09, 2019 · Aerco Benchmark Standard and Platinum condensing boilers are an extremely efficient investment, keep your investment running strong with two year maintenanceGet Price
Feb 18, 2007 · A Testco light camera has visually inspected the tubes at bends and are clogged. On top of that Have been informed by Aerco not to run at condensing temperature. The certified Aerco man says his boilers run at 6" after he cleans them. Manual says probally time to clean at 6".Get Price