boiler Agent capacity unit sq ft to tons
Capacity:1-20t/h
Rated thermal efficiency: 100-104%
Fixed working pressure: ≤1.6MPa
Applicable fuel:natural gas etc.
Capacity:0.7-14MW
Rated thermal efficiency:96-98%
Fixed working pressure:≤1.25MPa
Applicable fuel:Natural gas, light oil, etc.
Capacity:0.7-2.8Mw
Rated thermal efficiency: 97.2-106%
Fixed working pressure:0.1MPa
Applicable fuel:Natural gas, etc.
Capacity:2.8-7.0Mw
Rated thermal efficiency:≥105.5%
Fixed working pressure:-0.02MPa
Applicable fuel:Natural gas, etc.
Capacity:99Kw
Rated thermal efficiency:97.2-104.4%
Fixed working pressure:1.0MPa
Applicable fuel:Natural gas, etc.
Capacity:0.5-4.0 t/h
Rated thermal efficiency:98%
Fixed working pressure:≤1.25MPa
Applicable fuel:electric energy
Apr 30, 2019 · For instance, if you are looking at a boiler with a rating of 80,000 BTUh, you can safely assume that the unit's gross output is 80,000 BTUs, or 80 MBH (one MBH = 1,000 BTUh). There are other, less common ways of quantifying a boiler's heating capacity, like GPH (gallons of fuel oil consumed per hour) and sq. ft. of steam (volume of steam Get Price
A boilers capacity is usually expressed as kBtu/hour (1000 Btu/hour) and can be calculated as. W = (hg - hf) m (1) where. W = boiler capacity (Btu/h, kW) hg = enthalpy steam (Btu/lb, kJ/kg) hf = enthalpy condensate (Btu/lb, kJ/kg) m = steam evaporated (lb/h, kg/s)Get Price
Dec 13, 2010 · Other Useful Information: 1 SQ.FT. E.D.R. = 240 BTUH @215 ° F. 1 Boiler H.P. = 33493 BTU/Hr Where SpGr = Specific Gravity (Water is 1.0). Condensate Pump Sizing: . A: Pump Capacity = 2 x Actual GPM Condensate B: Minimum Receiver Size in Gallons = 1 minute x GPM found in part A C: Pump Head (In Feet) = Static Lift in Feet + Friction Losses in Feet + Pressure …Get Price
Jul 28, 2016 · → boiler capacity =11,110 kW * 0.9 ~=10,000 kW. Why is boiler capacity given in ton per hour? It is sometimes difficult to understand boiler capacity terminology because not all manufacturers stick to norms when advertising boiler capacities. World over, the capacity of boilers is stated in terms of: 1.) square feet of heating surface.Get Price
The Boiler Horsepower (BHP) is the amount of energy required to produce 34.5 pounds of steam per hour at a pressure and temperature of 0 Psig and 212 ℉, with feedwater at 0 Psig and 212 ℉. "Boiler horsepower, a unit of measurement of power of steam boilers" from Wiki.Get Price
There are 9 square feet of heating surface to each square foot of grate surface. A cubic foot of water contains 7.5 gallons and 1728 cubic inches, and weighs 62.5 lbs. Each nominal horsepower of a boiler requires 30 to 35 pounds of water per hour.Get Price
unit has 20 30 inch fans installed and there are four shared steel feed bins attached, each having a storage capacity of 20 tons. The plant shed and generators are attached to the poultry houses. The two 199kW biomass boilers were installed in 2013 and supply heat to the poultry houses. They have 13 years leftGet Price